Eddy current probes

Right Angle Surface Probe (90˚ tip, Single / Single Shielded, Bridge type)

Right Angle Surface Probe (90˚ tip, Single / Single Shielded, Bridge type)

Sensing element of eddy current probe is placed at the angle of 90˚ to the handle axis.

 

Designation

Tip Ø ‘D’, mm

Drop length, mm

Length, mm

Centre frequency

Connector

Material

SU200K5A4.5Dx6.4-105 B

4.5

6.4

105

200 kHz

Triax Lemo/Fischer

Fe/NFe

SU500K5A3Dx6.4-105 B

3

6.4

105

500 kHz

Triax Lemo/Fischer

Fe/NFe

SU500K5A4.5Dx6.4-105 B

4.5

6.4

105

500 kHz

Fe/NFe

SU500K5A4.5Dx12.7-105 B

4.5

12.7

105

500 kHz

Fe/NFe

SU2М5A2.5Dx2.7-105 B

2.5

2.7

105

2 MHz

NFe

SU2М5A3Dx2.7-105 B

3

2.7

105

2 MHz

NFe

SU2М5A3Dx6.4-105 B

3

6.4

105

2 MHz

NFe

SU2М5A3Dx12.7-105 B

3

12.7

105

2 MHz

NFe

SU6М5A2.5Dx6.4-105 B

2.5

6.4

105

6 MHz

NFe

 

SU

200K

5A

4.5D

x

6.4

-

105

B(Sh)

1

2

3

4

 

5

 

6

7

 

 

1. SU – surface probe for surface flaws detection.

2. Probe frequency:

“HZ” designates the Hz range; “К” designates the kHz range; “М” designates the MHz range.

3. Drop angle of a sensing element to the probe axis “5А” is 90.

4. Probe tip diameter, mm.

5. Drop length, mm.

6. Probe length, mm. Standard length of 105 mm (4.1") can be changed upon request.

7. Probe type designation: “B”. “B” – Bridge type probe.

Probes of standard type are manufactured unshielded. In case a shielded probe is required, when making an order, please indicate the letters ”Sh” (Shielded) at the end of a designation code.

 

Related Products: